ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads

Model: DU124

ZXY DU124 microphone transformer, fly-lead type, in the 1:4, 1:7 or 1:12 turns ratio. Stacked EI lamination core, high-dielectric-strength yellow Mylar tape over the winding, four pre-tinned leads with UL AWM style insulation at a nominal 40 ± 2 mm, body 16.5 x 12.0 x 25.0 mm, frequency range 20 Hz to 20 kHz.

型号
ZXY DU124
型号2
ZXY DU124
频率范围
20 Hz - 20 kHz

View all specifications →

Description

1. Product Name

ZXY DU124 microphone transformer, fly-lead type, in the 1:4, 1:7 or 1:12 turns ratio. Stacked EI lamination core, high-dielectric-strength yellow Mylar tape over the winding, four pre-tinned leads with UL AWM style insulation at a nominal 40 ± 2 mm, body 16.5 x 12.0 x 25.0 mm, frequency range 20 Hz to 20 kHz.

ZXY DU124, front view with the four fly leads rising from the bobbin
ZXY DU124, front view with the four fly leads rising from the bobbin
ZXY DU124 microphone transformer, three-quarter view, premium audio grade
ZXY DU124 microphone transformer, three-quarter view, premium audio grade

Overview. The part is built around a stacked EI lamination core, 7.5 mm across the lamination, with the winding occupying 13.0 mm of the 25.0 mm body height. The body measures 16.5 mm in front view and 12.0 mm in side view, so what it takes from a layout is a narrow footprint and a tall column.

The four leads come off the bobbin rather than out of pins. That is the whole point of this form: it can be routed into a microphone body, a flying harness or an existing assembly after the mechanical design is already fixed, where a pinned part would force a board revision.

2. Feature

Isolation that protects the upstream stage. the transformer couples the signal without a conductive path, so a fault or a DC offset on one side cannot take out the output stage that feeds it.

Voice and data coupling. wound for signal coupling in speech and data paths rather than for power transfer, which is what the 20 Hz to 20 kHz window is there to cover.

20 Hz to 20 kHz frequency range. the full audio band, so the part can sit in a microphone line, a preamp input or a line-level interface without being the element that limits bandwidth.

Ground-loop hum rejection. the isolation breaks the loop formed when two pieces of equipment are earthed separately, which is where the AC hum in a signal chain usually comes from.

Balanced and unbalanced use. reduces external interference in either configuration, so the same part serves a balanced microphone run and an unbalanced line inside a chassis.

Fly-lead termination. four pre-tinned leads of 40 ± 2 mm instead of PCB pins, for wiring into a microphone body, a harness or an existing assembly where no footprint is available.

Low-distortion, wide-response winding. tuned to hold speech intelligibility and audio fidelity at the same time, which is the compromise a microphone transformer has to make.

Stacked EI lamination core. precision-stacked laminations, taped over with high-dielectric-strength yellow Mylar, so the winding is insulated from the core edge.

Detailed view: pre-tinned leads with UL AWM style insulation, stacked EI core, yellow Mylar tape
Detailed view: pre-tinned leads with UL AWM style insulation, stacked EI core, yellow Mylar tape

The detailed view shows the three things that carry the performance of this part: the leads are pre-tinned and insulated to UL AWM style, the core is stacked from laminations rather than solid, and the winding is covered by high-dielectric-strength yellow Mylar tape before the core goes on. That tape layer is what the 1500 V withstand rating is measured across.

3. Advantage

Three ratios, one series. 1:4, 1:7 and 1:12 cover step-up needs from a modest level lift to a high-ratio microphone match, so one qualified part family can cover a product range.

Wiring flexibility. a lead-out part can be routed after the mechanical design is fixed, which is rarely true of a pinned transformer on a board.

Documented electrical set. inductance, DC resistance and dielectric withstand are published per ratio at 25 °C, so the part can be specified against numbers rather than by ear.

Consistent dielectric margin. all three variants are rated at 1500 V with a 1 mA leakage limit over 60 s, so the isolation figure does not have to be re-qualified when the ratio changes.

Tape insulation over the winding. high-dielectric-strength Mylar between the winding and the core, which is the layer that carries the withstand rating.

Pre-tinned leads. ready to solder without stripping or tinning at the bench, with UL AWM style insulation on the lead.

Custom designs available. the winding can be adapted to a target ratio, level or footprint, with factory-direct supply and stock on the standard variants.

Winding schematic: RED and BLACK on one winding, BLUE and YELLOW on the other, polarity dots marked
Winding schematic: RED and BLACK on one winding, BLUE and YELLOW on the other, polarity dots marked

Read the schematic before wiring the part. RED and BLACK sit on one winding with the polarity dot on the BLACK side; BLUE and YELLOW sit on the other with the dot on the BLUE side. The drawing identifies the pairs and the dots but does not mark which winding is primary, so take the pairing from the drawing and confirm the intended side with the factory before fixing a wiring order in your own drawing.

4. Application

Microphones. lavalier, camera and instrument microphones, where the transformer sits inside the body or at the connector end of the lead.

Microphone preamplifiers and isolation modules. as the input transformer or the isolating element in a preamp or a channel module.

Audio systems. signal isolation and noise elimination in high-end loudspeakers, home theatre and car audio, where separate earths put hum into the signal.

Communication equipment. signal coupling for telephones, fax machines, IP voice terminals and modems, where the line side has to stay isolated from the equipment side.

Industrial and broadcast systems. audio signal isolation and transmission in public address and conference systems, including runs between rooms and between racks.

Wired into a breadboard circuit, with a handheld meter connected across one winding
Wired into a breadboard circuit, with a handheld meter connected across one winding
Mounted on a printed circuit board assembly next to its supporting circuitry
Mounted on a printed circuit board assembly next to its supporting circuitry

Both views show the same thing in practice: the transformer sits at the boundary between two circuits that must not share a conductor. In the breadboard it is the element between the source and the measured side; on the board assembly it is wired in on its leads beside the circuitry it isolates. Neither placement needs a footprint, which is why the same part appears in both.

5. Application Specifications

The specification below is the data declared for this model at 25 °C: product data, the electrical table per turns ratio, outline dimensions, and construction.

5.1 Product specification

ItemDescription
ModelZXY DU124
Product nameMicrophone transformer, fly-lead (lead-out) type
Product categoryAudio isolation transformer / voice and data coupling transformer
Frequency range20 Hz to 20 kHz
Available turns ratios1:4, 1:7, 1:12
Termination4 × pre-tinned fly leads (lead-out wires)
Reference temperature25 °C for the electrical parameters

5.2 Electrical specification, three turns-ratio variants

Inductance is measured at 1 kHz and 0.3 V as a minimum; DC resistance carries a ±15% tolerance; dielectric withstand is 1500 V with a 1 mA leakage limit held for 60 s.

Turns ratioL1 at 1 kHz, 0.3 V minL2 at 1 kHz, 0.3 V minDCR1 ±15%DCR2 ±15%Hi-POT, 1 mA, 60 s
1:40.5 H4.0 H11 Ω84 Ω1500 V
1:71.0 H50 H23 Ω214 Ω1500 V
1:121.2 H100 H25 Ω483 Ω1500 V
Table 1 reproduces the specification sheet verbatim. That sheet prints the same header twice on the two inductance columns (1KHZ 0.3V MIN) and the same tolerance twice on the two DC resistance columns (±15%), so the two columns are labelled L1 and L2 and DCR1 and DCR2 here rather than primary and secondary. The pairs also do not scale as the square of the turns ratio in every row, which is consistent with the columns not being primary and secondary of the same winding pair. Treat the columns as published values for the variant and confirm which one is which before quoting inductance or DCR against an impedance.

5.3 Outline dimensions

DimensionMarked value
Overall length, front view16.5 mm
Overall depth, side view12.0 mm
Overall height, body excluding leads25.0 mm
Winding / bobbin height13.0 mm
Core width, lamination7.5 mm
Fly-lead length40 ± 2 mm
Outline drawing, unit mm: 16.5 mm wide, 12.0 mm deep, 25.0 mm body height, 13.0 mm winding height, 7.5 mm core, 40 ± 2 mm leads
Outline drawing, unit mm: 16.5 mm wide, 12.0 mm deep, 25.0 mm body height, 13.0 mm winding height, 7.5 mm core, 40 ± 2 mm leads
Lead colour coding RED / BLUE / YELLOW / BLACK against the outline
Lead colour coding RED / BLUE / YELLOW / BLACK against the outline
The outline drawing prints the 7.5 mm core width twice inside each view, rendered once as 7.5_2 and once as 7.5. The two are the same dimension with a different label, not a second size, so Table 3 lists it once. The 40 ± 2 mm lead length is dimensioned from the top face of the body to the cut end of the wire.

5.4 Construction and lead-out wires

ItemDescription
CorePrecision-stacked EI lamination core
Insulation over the windingHigh-dielectric-strength yellow Mylar tape
Leads4 × pre-tinned fly leads, UL AWM style insulation
Lead coloursRED, BLUE, YELLOW, BLACK
Lead length40 ± 2 mm nominal
Termination styleLead-out, no PCB pins
PolarityIdentified by the dot marking on the schematic
The schematic pairs RED with BLACK on one winding and BLUE with YELLOW on the other, with the polarity dot on the BLACK side of the first pair and on the BLUE side of the second. The drawing does not label which winding is primary, so the assignment above is the pairings and dots as drawn, not a primary/secondary claim: confirm the intended side with the factory before you specify a wiring order in a drawing.

6. Quality & Testing Assurance

Every unit is checked against the limits below, taken from the same specification sheet that supplies the electrical table. The three turns-ratio variants share one set of limits except for the inductance and resistance values themselves.

Test itemCondition / limit
Inductance L1 kHz, 0.3 V, minimum values as listed in Table 1
DC resistance, DCRTolerance ±15%
Dielectric withstand, Hi-POT1500 V, leakage limit 1 mA, 60 s
Reference temperature25 °C

Winding insulation uses high-dielectric-strength yellow Mylar tape, and the fly leads are pre-tinned for immediate soldering with UL AWM style insulation.

This page quotes the construction, dimensional, electrical and test data that the specification sheet declares for ZXY DU124. It states no weight, no MOQ and no price, and it carries no certificate number, so none of those are given here. The CCC, CE, RoHS and UL marks visible in one supplied rendering are not supported by a certificate in the documentation supplied with this model, so they are not claimed on this page; ask the factory for the certificate numbers if an offer depends on them.

Brand / manufacturer: ZXY, Shenzhen Zhixiangyuan Electronics Co., Ltd. and Huizhou Zhixiangyuan Technology Co., Ltd. http://www.zxycoil.com

Specifications

ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · Specifications
型号ZXY DU124
型号2ZXY DU124
频率范围20 Hz - 20 kHz
介电耐压1500 V, 1 mA, 60 s
引线长度40 ± 2 mm
外形尺寸16.5 x 12.0 x 25.0 mm(宽 x 深 x 高,本体)
绝缘绕组外层黄色聚酯薄膜胶带
铁芯精密叠装EI型叠片
端接4条预镀锡引线,红/蓝/黄/黑
匝数比1
产品类型麦克风音频隔离变压器,引线型

Only supplied parameters are shown. Please confirm any unlisted electrical performance, test conditions, tolerances and customization options with our engineers. The final specification sheet takes precedence.

Product Images & Drawings

View the available product images and drawings below. Click to open the original. Customized products are subject to the agreed specifications and drawings.

ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings1
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 1View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings2
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 2View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings3
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 3View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings4
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 4View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings5
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 5View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings6
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 6View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings7
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 7View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings8
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 8View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings9
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 9View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings10
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 10View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings11
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 11View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings12
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 12View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings13
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 13View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings14
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 14View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings15
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 15View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings16
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 16View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings17
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 17View Original
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads — Product Images & Drawings18
ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads · 18View Original

Downloads

No specification sheet has been uploaded for this model yet. Use the inquiry form below to request parameters, dimension drawings or sample information.

Selection & Customization Requirements

To help confirm a suitable model and specification, please provide:

  • Your equipment, application, operating environment and temperature range.
  • As applicable: inductance, turns ratio or impedance, operating frequency, voltage, current and insulation requirements.
  • Size limits, mounting method, pin spacing, and any existing drawings or reference samples.
  • Sample quantity, estimated order volume and desired delivery date.
Request Specifications / Selection Support

Frequently Asked Questions

Common procurement questions about ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads.

What is ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads?

ZXY DU124 microphone transformer, fly-lead type, in the 1:4, 1:7 or 1:12 turns ratio. Stacked EI lamination core, high-dielectric-strength yellow Mylar tape over the winding, four pre-tinned leads with UL AWM style insulation at a nominal 40 ± 2 mm, body 16.5 x 12.0 x 25.0 mm, frequency range 20 Hz to 20 kHz.

Can ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads be customized to our specifications?

Yes. Shenzhen ZhiXiangyuan Electronics Co., Ltd. provides OEM/ODM services. Inductance, turns ratio, current rating, core material, size and terminal style can all be customized according to your drawings or samples.

What is the MOQ and lead time for ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads?

MOQ is negotiable based on the specific model and order quantity. Typical lead time is 1-3 weeks for standard items and 2-4 weeks for customized orders. Contact our sales team for an exact quotation.

Do you provide samples of ZXY DU124 Microphone Transformer, Fly-Lead Type, 20 Hz - 20 kHz, Turns Ratio 1:4 / 1:7 / 1:12, Stacked EI Core, 16.5 x 12.0 x 25.0 mm, Four Pre-Tinned Leads?

Yes, samples are available for evaluation before bulk orders. Please send us your requirements and shipping details to request samples.

What is the model number of this product?

The model number is DU124. Custom model numbers can be assigned for OEM orders.

Send Us a Message

Tell us your requirements and our engineers will reply within 24 hours.